Type HR reverse circulation pumps are designed for fluids &
chemicals with relatively high vapour pressure, low specific
gravity, low specific heat liquids. Liquids with steep vapor
pressure curves may vaporize on picking up the motor heat and result
in cavitations conditions The circulation/pumping fluid is passed
from the casing volute chamber into the rotor chamber through the
front bearing housing. After being extracted from the outlet of rear
bearing housing, the liquid is returned to vapor zone in the suction
tank, through the reverse circulation line.
Operating
Range
| Flow |
1 to 500 m3/hr |
| Head |
upto 140m, higher head upon request |
| Temp |
-80 to 100° C |
| Pressure |
atmospheric to 15 kg/cm2 |
Applications
- Ammonia
- Freon and Refrigerants
- Anhydrous Hydrofluoric Acid
- Methylene Chloride
- Aceton
- Acetaldehyde
- Formaldehyde
- Vinyl Acetate
- Acrylonitril Etc.
|
|